CJ3Z42-3

Circuit Breakers

CIRCUIT BREAKER

CJ3Z42-3

5925-01-073-2546

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    7.000 inches nominal

  • Boss Height

    0.218 inches nominal

  • End Item Identification

    air route surveillance radar 3 (arsr3)

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    6.126 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    125.0 amperes ac all locations

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.359 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Body Width

    4.500 inches nominal

  • Mounting Surface To Terminal End Distance

    4.219 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct all locations and 190.000 maximum at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...