CVC2523-20

Circuit Breakers

CIRCUIT BREAKER

CVC2523-20

5925-01-073-5773

5925 - Circuit Breakers

Triumph Aerostructures Llc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Nonturn Device Width

    0.093 inches nominal

  • Actuator Position Designation

    at pole one

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.094 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Pole Quantity

    1

  • Nonturn Device Length

    0.045 inches nominal

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.250 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.00 dc single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Nonturn Device Radius

    0.375 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    136.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...