40-3175-01
Switches
SWITCH,THERMOSTATIC
40-3175-01
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
16.0 amperes resistive load .
-
Contact Load Current Rating
8.0 amperes resistive load .
-
Contact Adjustability
deactuation point adjustable, preset and actuation point adjustable, preset
-
Mounting Facility Pattern
two position in-line
-
Nominal Thread Size
0.164 inches .
-
Contact Action Stimulus
increase
-
Thread Quantity Per Inch
32 .
-
Temp Sensing Element Type
capillary tube-bulb
-
Bulb Length
1.940 inches nominal
-
Capillary Tube Length
18.0 inches nominal
-
Body Length
1.500 inches nominal
-
Overall Width
1.461 inches nominal
-
Overall Height
2.380 inches nominal
-
Contact Adjustment Range
-16.50/+11.00 actuation point degrees fahrenheit and -16.50/+11.00 deactuation point degrees fahrenheit
-
Contact Adjustment Type
external deactuation point dial and external actuation point dial
-
Contact Stimulus Rating
-3.50 actuation point nominal degrees fahrenheit and 3.50 deactuation point nominal degrees fahrenheit
-
Contact Voltage Rating In Volts
230.0 ac at sea level .
-
Media For Which Designed
gas
-
Style Designator
cstyl 77
-
Thread Series Designator
unc .
-
Thread Class
3b .
-
Overall Length
2.500 inches nominal
-
Body Width
1.114 inches nominal
-
Body Height
1.531 inches nominal
-
Distance Between Mounting Facility Centers
2.188 inches nominal
-
Bulb Diameter
0.300 inches nominal
-
Mounting Method
bracket and threaded hole
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Terminal Type
quick disconnect, male
-
Contact Voltage Rating In Volts
115.0 ac at sea level .