APL3331-512-9-1

Circuit Breakers

CIRCUIT BREAKER

APL3331-512-9-1

5925-01-074-3043

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Trip Release Characteristic

    instantaneous fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 fourth location

  • Frequency In Hertz

    60.0 third location

  • Internal Trip Release Configuration

    shunt trip first location

  • Internal Trip Release Configuration

    shunt trip second location

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc fourth location

  • Terminal Type And Quantity

    11 threaded stud

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Internal Trip Release Configuration

    shunt trip third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    any acceptable first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    any acceptable second location

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    any acceptable third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac third location

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Frequency In Hertz

    60.0 first location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Frequency In Hertz

    60.0 second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • Internal Trip Release Configuration

    series trip fourth location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Circuit Protection Type

    overvoltage fourth location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac second location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Boss Height

    0.150 inches nominal

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Width

    3.015 inches maximum

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...