8857126-18

Circuit Breakers

CIRCUIT BREAKER

8857126-18

5925-01-075-7140

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    2.250 inches maximum

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Criticality Code Justification

    cbbl

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    3 alarm

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Center To Center Distance Between Terminals Parallel To Width

    0.715 inches minimum and 0.745 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Features Provided

    high inrush protection

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Switch Terminal Type

    pin

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.715 inches minimum and 0.745 inches maximum

  • Switch Location And Position Designation

    internal at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.500 minimum at 200 pct all locations and 60.000 maximum at 200 pct all locations

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    2.151 inches maximum

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...