Technical Characteristics

  • Body Length

    1.990 inches minimum and 2.010 inches maximum

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.650 inches minimum and 1.670 inches maximum

  • Boss Height

    0.120 inches minimum and 0.140 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and humidity resistant and shock resistant and vibration resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    1.550 inches minimum and 1.570 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.935 inches minimum and 1.955 inches maximum

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 8.000 maximum at 200 pct

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...