APL1R-778-1

Circuit Breakers

CIRCUIT BREAKER

APL1R-778-1

5925-01-076-4460

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.469 inches minimum and 2.531 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.031 inches minimum and 2.093 inches maximum

  • Boss Height

    0.094 inches minimum and 0.156 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    4.250 ounces

  • Frequency In Hertz

    60.0 single location

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 10.000 maximum at 200 pct

  • Switch Location And Position Designation

    internal at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2.000 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location

  • Terminal Type And Quantity

    2 threaded stud

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and vibration resistant and shock resistant

  • Nominal Thread Size

    0.138 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.828 inches minimum and 2.952 inches maximum

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    1.906 inches minimum and 1.968 inches maximum

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Body Style

    12a single pole type

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...