APL1R-778-1
Circuit Breakers
CIRCUIT BREAKER
APL1R-778-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.469 inches minimum and 2.531 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.031 inches minimum and 2.093 inches maximum
-
Boss Height
0.094 inches minimum and 0.156 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 threaded hole
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Thread Series Designator
unc
-
Unpackaged Unit Weight
4.250 ounces
-
Frequency In Hertz
60.0 single location
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Switch Terminal Type
tab, solder lug
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 10.000 maximum at 200 pct
-
Switch Location And Position Designation
internal at pole one
-
Internal Trip Release Configuration
series trip single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Method
magnetic single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2.000 ac single location
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
-
Terminal Type And Quantity
2 threaded stud
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Inclosure Protection Type For Which Designed
fungus resistant and vibration resistant and shock resistant
-
Nominal Thread Size
0.138 inches
-
Auxiliary Switch Function And Quantity
1 alarm
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Reset Method
manual
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
2.828 inches minimum and 2.952 inches maximum
-
Fragility Factor
moderately rugged
-
Switch Contact Arrangement
single pole, double throw
-
Center To Center Distance Between Terminals Parallel To Length
1.906 inches minimum and 1.968 inches maximum
-
Body Width
0.719 inches minimum and 0.781 inches maximum
-
Body Style
12a single pole type
-
Thread Pitch Diameters
0.1177 to 0.1214 inches