JA2-A2-A-15-2

Circuit Breakers

CIRCUIT BREAKER

JA2-A2-A-15-2

5925-01-076-6377

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.718 inches minimum and 0.782 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.718 inches minimum and 0.782 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Unpackaged Unit Weight

    5.000 ounces

  • Switch Contact Arrangement

    single pole, double throw

  • Body Length

    1.968 inches minimum and 2.032 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    1.528 inches minimum and 1.592 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Arc Quenching Method

    magnetic blowout

  • Body Width

    1.468 inches minimum and 1.532 inches maximum

  • Boss Height

    0.098 inches minimum and 0.162 inches maximum

  • Switch Location And Position Designation

    internal at each pole

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Mounting Surface To Terminal End Distance

    2.233 inches minimum and 2.297 inches maximum

  • Switch Terminal Type

    quick disconnect, male

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.628 inches minimum and 1.692 inches maximum

  • Terminal Type And Quantity

    4 quick disconnect, male

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...