M4012M
Switches
SWITCH,PRESSURE
M4012M
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustment Range
p1.00/p7.00 actuation point pounds per square inch
-
Contact Adjustment Type
external actuation point screw
-
Contact Voltage Rating In Volts
24.0 dc at sea level
-
Pressure Connector Type
external seat-gasket seal,threaded external
-
Outside Diameter
0.125 inches nominal
-
Pressure Switch Type
differential
-
Terminal Type
tab w/screw
-
Contact Adjustability
deactuation point not adjustable and actuation point adjustable,preset
-
Contact Stimulus Rating
4.00 actuation point nominal pounds per square inch and 1.00 deactuation point nominal pounds per square inch
-
Media For Which Designed
gas or liquid
-
Style Designator
cylindrical
-
Thread Series Designator
npt
-
Thread Length
0.375 inches nominal
-
Overall Length
2.000 inches nominal
-
Overall Height
1.687 inches nominal
-
Overall Width
1.687 inches nominal
-
Body Diameter
1.437 inches nominal
-
Body Length
0.750 inches nominal
-
Mounting Method
inlet connection
-
Thread Quantity Per Inch
27
-
Contact Action Stimulus
increase
-
Proof Pressure
150.00 pounds per square inch
-
Nominal Thread Size
0.125 inches
-
Nonpile-Up Contact Arrangement
1 pole,double throw,one position momentary
-
Contact Load Current Rating
4.0 amperes resistive load