MIL-C-5809

Circuit Breakers

CIRCUIT BREAKER

MIL-C-5809

5925-01-077-5833

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 35.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc single location

  • Thread Series Designator

    un

  • Unpackaged Unit Weight

    0.062 pounds

  • Case Material

    plastic

  • ~1

    data on certain environmental and performance

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.781 inches maximum

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Specification/Standard Data

    81349-ms14105/35 government standard

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.094 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 115.0 dc single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...