AP-1-1-7-1-153

Circuit Breakers

CIRCUIT BREAKER

AP-1-1-7-1-153

5925-01-077-5835

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac and 15.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct single location

  • Frequency In Hertz

    560.0 or 400.0

  • Unpackaged Unit Weight

    1.800 ounces

  • Terminal Type And Quantity

    2 wire hook

  • Body Style

    2a single pole type

  • Thread Series Designator

    unef

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Nominal Thread Size

    0.375 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 1000.0 dc single location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Fragility Factor

    moderately rugged

  • Case Material

    metal

  • Body Width

    0.625 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...