SM600BA60N1

Circuit Breakers

CIRCUIT BREAKER

SM600BA60N1

5925-01-078-6451

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Body Width

    1.200 inches maximum

  • Reset Method

    automatic

  • Mounting Surface To Terminal End Distance

    4.030 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    13.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3600.0 ac single location and 3600.0 dc single location

  • Frequency In Hertz

    400.0 single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Characteristic

    time delay single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.940 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Case Material

    metal

  • Pole Quantity

    1

  • Overall Length

    3.250 inches maximum

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location and 60.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...