UPL-111-1-4-2-303

Circuit Breakers

CIRCUIT BREAKER

UPL-111-1-4-2-303

5925-01-078-6675

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    11.100 ounces

  • Frequency In Hertz

    400.0

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.490 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Internal Trip Release Configuration

    series trip

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Actuator Position Designation

    at each pole

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Body Width

    2.265 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...