203-111-2236-10

Circuit Breakers

CIRCUIT BREAKER

203-111-2236-10

5925-01-080-5004

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Body Height

    1.740 inches minimum and 1.770 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.009 minimum at 500 pct all locations and 0.070 minimum at 300 pct all locations and 9.000 maximum at 200 pct all locations and 0.500 minimum at 200 pct all locations and 0.300 maximum at 300 pct all locations and 0.900 maximum at 500 pct all locations

  • Case Material

    plastic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Length

    1.970 inches minimum and 2.030 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Terminal Type And Quantity

    6 tab, solder lug

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Time Per Pole In Seconds

    2.000 minimum all locations and 60.000 maximum all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.595 inches minimum and 0.655 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Mounting Facility Type And Quantity

    4 clip

  • Body Width

    1.915 inches minimum and 1.945 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.095 inches minimum and 0.125 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...