MIL-C-83383/4
Circuit Breakers
CIRCUIT BREAKER
MIL-C-83383/4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
50000.0 ac all locations and 50000.0 dc all locations
-
Trip Release Method
thermal all locations
-
Terminal Type And Quantity
6 threaded stud
-
Test Data Document
81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Switch Contact Arrangement
single pole, double throw
-
Unthreaded Mounting Hole Diameter
0.167 inches minimum and 0.177 inches maximum
-
Case Material
metal
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
14.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations
-
Frequency In Hertz
400.0 all locations
-
Switch Current Rating And Type In Amps
3.0 ac and 1.5 dc
-
Auxiliary Switch Function And Quantity
1 alarm
-
Overall Width
3.690 inches nominal
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Specification/Standard Data
81349--83383/04-05 government specification
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Body Style
rectangular dimensional envelope
-
Reset Method
manual
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations and 30.0 dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
Inclosure Protection Type For Which Designed
corrosion resistant and fungus resistant and hermetically sealed
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations
-
Overall Height
3.250 inches maximum
-
Switch Voltage Rating And Type In Volts
115.0 ac and 28.0 dc
-
Overall Length
4.260 inches nominal