MIL-PRF-83383/4

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-83383/4

5925-01-080-5755

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50000.0 ac all locations and 50000.0 dc all locations

  • Trip Release Method

    thermal all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Test Data Document

    81349-mil-c-83383 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Switch Contact Arrangement

    single pole, double throw

  • Unthreaded Mounting Hole Diameter

    0.167 inches minimum and 0.177 inches maximum

  • Case Material

    metal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    14.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 all locations

  • Switch Current Rating And Type In Amps

    3.0 ac and 1.5 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Overall Width

    3.690 inches nominal

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Specification/Standard Data

    81349--83383/04-05 government specification

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Style

    rectangular dimensional envelope

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations and 30.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant and hermetically sealed

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Overall Height

    3.250 inches maximum

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Overall Length

    4.260 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...