Technical Characteristics

  • Body Width

    3.093 inches minimum and 3.123 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.535 inches minimum and 3.565 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.011 inches minimum and 1.041 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.011 inches minimum and 1.041 inches maximum

  • Mounting Surface To Terminal End Distance

    3.535 inches minimum and 3.565 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Nominal Thread Size

    0.136 inches

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    5.110 inches minimum and 5.140 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.735 inches minimum and 2.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.205 inches minimum and 0.235 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 200.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Unpackaged Unit Weight

    2.000 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...