AM1516MG3-15-125VACC3

Circuit Breakers

CIRCUIT BREAKER

AM1516MG3-15-125VACC3

5925-01-084-2946

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 nominal at 150 pct single location and 4.000 nominal at 100 pct single location and 1.000 nominal at 125 pct single location and 0.150 nominal at 200 pct single location and 0.030 nominal at 400 pct single location and 0.020 nominal at 500 pct

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    3.167 inches minimum and 3.311 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.980 inches minimum and 1.000 inches maximum

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Terminal Type And Quantity

    2 threaded stud

  • ~1

    single location and 0.003 nominal at 1000 pct sing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...