TLA800-5XX2

Filters and Networks

FILTER,LOW PASS

TLA800-5XX2

5915-01-084-6270

5915 - Filters and Networks

Telonic Berkeley Inc.

FILTER,LOW PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reference Frequency Per Function

    400.0 megahertz 1st low pass

  • Reference Frequency Per Function

    400.0 megahertz 3rd low pass

  • Reference Frequency Per Function

    400.0 megahertz 4th low pass

  • Input Impedance Per Function W/Load

    50.0 ohms 1st low pass

  • Output Impedance Per Function W/Source Across Input

    50.0 ohms 1st low pass

  • Output Impedance Per Function W/Source Across Input

    50.0 ohms 2nd low pass

  • Output Impedance Per Function W/Source Across Input

    50.0 ohms 5th low pass

  • Voltage Standing Wave Ratio Per Function

    1.5 2nd low pass

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    2 terminal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 1st low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 4th low pass

  • Functional Terminal Type And Quantity

    1 connector,receptacle output

  • Specified Frequencies Of Discrimination Per Function

    1.00 megahertz 3rd low pass and 800.00 megahertz 3rd low pass and 11.94 megahertz 3rd low pass and 35.00 megahertz 3rd low pass

  • Specified Frequencies Of Discrimination Per Function

    1.00 megahertz 4th low pass and 800.00 megahertz 4th low pass and 11.94 megahertz 4th low pass and 35.00 megahertz 4th low pass

  • Body Material

    metal

  • Frequency Band Width Per Function

    1.00 megahertz 4th low pass and 800.00 megahertz 4th low pass

  • Frequency Band Width Per Function

    1.00 megahertz 5th low pass and 800.00 megahertz 5th low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 5th low pass and 1.0 maximum 5th low pass and 60.0 minimum 5th low pass and 60.0 minimum 5th low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 megahertz 4th low pass and 800.0 megahertz 4th low pass

  • Body Length

    3.030 inches nominal

  • Operating Temp Range

    m40.0/p71.0 deg celsius

  • Reference Frequency Per Function

    400.0 megahertz 2nd low pass

  • Reference Frequency Per Function

    400.0 megahertz 5th low pass

  • Input Impedance Per Function W/Load

    50.0 ohms 2nd low pass

  • Input Impedance Per Function W/Load

    50.0 ohms 3rd low pass

  • Input Impedance Per Function W/Load

    50.0 ohms 4th low pass

  • Input Impedance Per Function W/Load

    50.0 ohms 5th low pass

  • Output Impedance Per Function W/Source Across Input

    50.0 ohms 3rd low pass

  • Output Impedance Per Function W/Source Across Input

    50.0 ohms 4th low pass

  • Voltage Standing Wave Ratio Per Function

    1.5 1st low pass

  • Voltage Standing Wave Ratio Per Function

    1.5 3rd low pass

  • Voltage Standing Wave Ratio Per Function

    1.5 4th low pass

  • Voltage Standing Wave Ratio Per Function

    1.5 5th low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 2nd low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 megahertz 5th low pass and 800.0 megahertz 5th low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 megahertz 3rd low pass and 800.0 megahertz 3rd low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 megahertz 2nd low pass and 800.0 megahertz 2nd low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 megahertz 1st low pass and 800.0 megahertz 1st low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 4th low pass and 1.0 maximum 4th low pass and 60.0 minimum 4th low pass and 60.0 minimum 4th low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 3rd low pass and 1.0 maximum 3rd low pass and 60.0 minimum 3rd low pass and 60.0 minimum 3rd low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 2nd low pass and 1.0 maximum 2nd low pass and 60.0 minimum 2nd low pass and 60.0 minimum 2nd low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 1st low pass and 1.0 maximum 1st low pass and 60.0 minimum 1st low pass and 60.0 minimum 1st low pass

  • Frequency Band Width Per Function

    1.00 megahertz 3rd low pass and 800.00 megahertz 3rd low pass

  • Frequency Band Width Per Function

    1.00 megahertz 2nd low pass and 800.00 megahertz 2nd low pass

  • Frequency Band Width Per Function

    1.00 megahertz 1st low pass and 800.00 megahertz 1st low pass

  • Specified Frequencies Of Discrimination Per Function

    1.00 megahertz 5th low pass and 800.00 megahertz 5th low pass and 11.94 megahertz 5th low pass and 35.00 megahertz 5th low pass

  • Specified Frequencies Of Discrimination Per Function

    1.00 megahertz 2nd low pass and 800.00 megahertz 2nd low pass and 11.94 megahertz 2nd low pass and 35.00 megahertz 2nd low pass

  • Specified Frequencies Of Discrimination Per Function

    1.00 megahertz 1st low pass and 800.00 megahertz 1st low pass and 11.94 megahertz 1st low pass and 35.00 megahertz 1st low pass

  • Functional Terminal Type And Quantity

    1 connector,receptacle input

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 5th low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 3rd low pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...