807659
Coils and Transformers
TRANSFORMER,POWER
807659
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
250.0 milliamperes dc maximum single component 3rd secondary
-
Winding Function And Quantity
2 primary single component and 4 secondary single component
-
Body Width
1.375 inches maximum
-
Winding Operating Voltage
115.00 ac volts nominal single component all primary and 125.00 ac volts nominal single component all primary
-
Winding Operating Current
15.0 milliamperes dc maximum single component 4th secondary
-
Inclosure Type
fully inclosed
-
Frequency Rating
45.0 hertz minimum single component and 440.0 hertz maximum single component
-
Winding Operating Voltage
185.00 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
23.80 ac volts nominal single component 1st secondary
-
Terminal Type And Quantity
15 pin
-
Reliability Indicator
not established
-
Winding Shielding Method
internal shield grounded to core and brought out to terminal single component
-
Mounting Method
terminal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
23.80 ac volts nominal single component 2nd secondary
-
Body Length
2.250 inches maximum
-
Winding Operating Current
150.0 milliamperes dc maximum single component 1st secondary
-
Winding Operating Voltage
12.00 ac volts nominal single component 3rd secondary
-
Body Height
1.625 inches nominal
-
Winding Operating Current
150.0 milliamperes dc maximum single component 2nd secondary