Technical Characteristics

  • Nominal Thread Size

    0.438 inches

  • Body Width

    1.100 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 screw

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.673 inches minimum and 0.735 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Thread Series Designator

    un

  • Case Material

    plastic

  • Body Height

    1.350 inches nominal

  • Trip Release Method

    thermal all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum all locations

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    thd bushing

  • Center To Center Distance Between Terminals Parallel To Width

    0.770 inches minimum and 0.834 inches maximum

  • Body Length

    2.380 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 500 pct all locations and 2.000 maximum at 500 pct all locations and 0.100 minimum at 1000 pct all locations and 4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations and 0.530 maximum at 1000 pct all

  • ~1

    locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...