9TC2-25
Circuit Breakers
CIRCUIT BREAKER
9TC2-25
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Thread Series Designator
uns
-
Case Material
plastic
-
Body Height
1.350 inches nominal
-
Trip Release Method
thermal all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 500 pct all locations and 2.000 maximum at 500 pct all locations and 0.100 minimum at 1000 pct all locations and 20.000 maximum at 200 pct all locations and 4.000 minimum at 200 pct all locations and 0.530 maximum at 1000 pct all
-
~1
locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum all locations
-
Bushing Length
0.250 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
thd bushing
-
Center To Center Distance Between Terminals Parallel To Width
0.770 inches minimum and 0.834 inches maximum
-
Body Length
2.380 inches nominal
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.438 inches
-
Body Width
1.100 inches maximum
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Main Contact Tripping Mechanism Type
trip free
-
Terminal Type And Quantity
6 screw
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Frequency In Hertz
400.0 all locations
-
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.735 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations