3360005-009
Circuit Breakers
CIRCUIT BREAKER
3360005-009
Northrop Grumman Systems Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
92755-3360005 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.085 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations
-
Terminal Type And Quantity
6 wire hook
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc third location
-
Bushing Length
0.380 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac second location
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 1000.0 dc all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Frequency In Hertz
60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Body Width
1.937 inches maximum
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Body Length
1.562 inches maximum
-
Inclosure Protection Type For Which Designed
vibrationproof and shockproof and hermetically sealed
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Thread Series Designator
unef
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations