3360005-009

Circuit Breakers

CIRCUIT BREAKER

3360005-009

5925-01-086-6404

5925 - Circuit Breakers

Northrop Grumman Systems Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    92755-3360005 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.085 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 wire hook

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc third location

  • Bushing Length

    0.380 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac second location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Body Width

    1.937 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Body Length

    1.562 inches maximum

  • Inclosure Protection Type For Which Designed

    vibrationproof and shockproof and hermetically sealed

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Thread Series Designator

    unef

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...