6N-AA5-N2C1A

Switches

SWITCH,PRESSURE

6N-AA5-N2C1A

5930-01-087-5835

5930 - Switches

Sor Inc

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Height

    4.812 inches nominal

  • Terminal Type

    connector, receptacle

  • Contact Adjustment Type

    external deactuation point hex nut and external actuation point hex nut

  • Body Length

    3.312 inches nominal

  • Thread Series Designator

    npt single pressure connection

  • Contact Stimulus Rating

    15.00 differential point minimum pounds per square inch and 50.00 differential point maximum pounds per square inch

  • Distance Between Mounting Facility Centers

    2.500 inches nominal

  • Operating Temp Rating

    -40.0 deg celsius minimum and 80.0 deg celsius maximum

  • Overall Width

    1.750 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Inside Diameter

    0.250 inches nominal single connection

  • Frequency In Hertz

    60.0 single voltage

  • Proof Pressure

    2500.00 pounds per square inch

  • Contact Load Current Rating

    10.0 amperes resistive load single voltage

  • Contact Voltage Rating In Volts

    250.0 ac at sea level single voltage

  • Sensing Element Burst Pressure

    1500.00 pounds per square inch

  • Contact Adjustability

    deactuation point adjustable, preset and actuation point adjustable, preset

  • Nonpile-Up Contact Arrangement

    2 pole, single throw, normally closed, momentary action

  • Style Designator

    rectangular

  • Thread Quantity Per Inch

    18 single pressure connection

  • Media For Which Designed

    gas or liquid

  • Pressure Connector Type

    swivel nut, flareless, threaded internal single connection

  • Features Provided

    electrical access port

  • Pressure Switch Type

    gage

  • Overall Length

    3.750 inches nominal

  • Nominal Thread Size

    0.250 inches single pressure connection

  • Mounting Facility Pattern

    two position in-line

  • Body Height

    3.312 inches nominal

  • Contact Action Stimulus

    increase

  • Mounting Method

    base and unthreaded hole

  • Contact Adjustment Range

    +10.00/+180.00 actuation point pounds per square inch and +10.00/+180.00 deactuation point pounds per square inch

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...