51731101

Circuit Breakers

CIRCUIT BREAKER

51731101

5925-01-087-9235

5925 - Circuit Breakers

Control Data Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac single location

  • Frequency In Hertz

    400.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 65.0 dc

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Switch Current Rating And Type In Amps

    10.0 ac and 10.0 dc

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 22.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...