6TC2-10B

Circuit Breakers

CIRCUIT BREAKER

6TC2-10B

5925-01-088-2837

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    locations

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Body Width

    0.730 inches minimum and 0.770 inches maximum

  • Thread Series Designator

    uns

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.593 inches minimum and 0.655 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Body Length

    1.840 inches maximum

  • Terminal Type And Quantity

    6 screw

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Body Height

    1.319 inches minimum and 1.381 inches maximum

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    thd bushing

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct all locations and 4.000 minimum at 200 pct all locations and 0.400 minimum at 500 pct all locations and 2.000 maximum at 500 pct all locations and 0.100 minimum at 1000 pct all locations and 0.530 maximum at 1000 pct all

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...