HE1-B2-28VDC-0.25A-1
Circuit Breakers
CIRCUIT BREAKER
HE1-B2-28VDC-0.25A-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Contact Arrangement
single pole,double throw
-
Mounting Surface To Terminal End Distance
1.700 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
250.0 milliamperes dc
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Location And Position Designation
internal at pole one
-
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and moisture resistant and hermetically sealed
-
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
-
Terminal Type And Quantity
2 wire hook
-
Bushing Length
0.375 inches nominal
-
Body Length
1.562 inches maximum
-
Body Width
0.625 inches maximum
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
750.0 dc
-
Trip Release Method
magnetic-hydraulic
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 6.000 maximum at 200 pct
-
Switch Terminal Type
tab,solder lug
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Unpackaged Unit Weight
0.131 pounds
-
Thread Series Designator
unef