A-2999
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
A-2999
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Mounting Facility Type And Quantity
8 threaded hole
-
Operating Current Rating Per Function In Amps
3.0 3rd radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug output 2nd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Nominal Thread Size
0.138 inches
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Height
1.750 inches nominal
-
Body Length
3.500 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
-
Body Width
3.500 inches nominal
-
Mounting Facility Screw Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Operating Temp Range
-40.0/+65.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference