0222-730

Coils and Transformers

TRANSFORMER,POWER

0222-730

5950-01-090-1067

5950 - Coils and Transformers

Guidance Technology Inc

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Function And Quantity

    1 primary single component and 1 secondary single component

  • Mounting Method

    unthreaded hole single group

  • Winding Operating Voltage

    30.00 ac volts nominal single component single secondary

  • Terminal Type And Quantity

    5 tab, solder lug

  • Reliability Indicator

    not established

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Voltage

    115.00 ac volts nominal single component single primary

  • Winding Operating Current

    150.0 milliamperes ac maximum single component single secondary

  • Body Height

    1.800 inches maximum

  • Body Width

    1.500 inches nominal

  • Mounting Hole Diameter

    0.170 inches nominal single group

  • Body Length

    1.500 inches nominal

  • Mounting Facility Quantity

    2 single group

  • Distance Between Mounting Facility Centers

    1.625 inches nominal single mounting facility single center group

  • Frequency Rating

    50.0 hertz minimum single component and 420.0 hertz maximum single component

  • Inclosure Type

    fully inclosed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...