7MC1-3-3

Circuit Breakers

CIRCUIT BREAKER

7MC1-3-3

5925-01-090-4113

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    explosion proof and fungus resistant

  • Switch Terminal Type

    pin

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 130.0 dc

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.006 minimum at 200 pct and 0.020 maximum at 200 pct single location

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Unpackaged Unit Weight

    0.125 pounds

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    0.750 inches minimum and 1.781 inches maximum

  • Body Width

    0.625 inches minimum and 0.656 inches maximum

  • Case Material

    plastic

  • Body Style

    1a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.781 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    1.638 inches minimum and 1.669 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.250 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People