CD2-B2B5-70-2
Circuit Breakers
CIRCUIT BREAKER
CD2-B2B5-70-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
5.790 inches minimum and
-
Body Width
2.062 inches minimum and
-
Body Width
2.072 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.557 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and
-
Body Style
8c multipole-multiple actuator type
-
Mounting Slot Width
0.178 inches nominal
-
Body Length
5.810 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
3.537 inches minimum and
-
Center To Center Distance Between Terminals Parallel To Width
1.036 inches maximum
-
Unthreaded Mounting Hole Diameter
0.164 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.580 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.036 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Boss Height
0.229 inches maximum
-
Mounting Surface To Terminal End Distance
3.431 inches maximum
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
2 unthreaded hole and
-
Mounting Facility Type And Quantity
4 threaded hole and
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Auxiliary Switch Function And Quantity
1 alarm
-
Internal Trip Release Configuration
series trip first location
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 maximum at 200 pct all locations
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Current Rating And Type In Amps
1.0 dc
-
Iii Unpackaged Unit Weight
1.620 pounds
-
Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.560 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and
-
Boss Height
0.209 inches minimum and
-
Mounting Surface To Terminal End Distance
3.287 inches minimum and
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 slot
-
Iii Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
70.0 amperes dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
shunt trip second location
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct and
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
2.5 ac and
-
Switch Voltage Rating And Type In Volts
250.0 ac and
-
Switch Voltage Rating And Type In Volts
50.0 dc
-
Terminal Type And Quantity
4 threaded stud