MS27400-6X
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MS27400-6X
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Cubic Measure
2.254 cubic inches
-
Precious Material
gold
-
Precious Material And Location
terminal surfaces gold
-
Purpose For Which Designed
specific
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Specification/Standard Data
81349--83536/15-022m government specification
-
Arc Quenching Method
air
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Case Material
metal
-
Features Provided
polarized
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Mounting Facility Pattern
triangle single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Overall Width
1.025 inches maximum
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
~1
reflecting general type data on certain environmental
-
Test Data Document
81349-mil-r-83536 specification specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications,
-
Special Features
failure rate level 1 persent per 10,000 cycles
-
Coil Quantity
1
-
Terminal Type And Quantity
14 pin all functions
-
Winding Dc Resistance Rating
290.0 ohms nominal single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac inductive load and 8.0 amperes dc inductive load
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Fragility Factor
moderately rugged
-
Nominal Operating Current Rating And Type
120.0 milliamperes dc single winding
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Height
1.280 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.421 inches nominal single mounting facility