M39019/02-202

Circuit Breakers

CIRCUIT BREAKER

M39019/02-202

5925-01-092-2468

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac and 50.0 milliamperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    instantaneous single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.375 inches

  • Switch Terminal Type

    tab, solder lug

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    50.0 grams

  • Thread Series Designator

    unef

  • Specification/Standard Data

    81349-mil-prf-39019/2 government specification

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc single location

  • Trip Release Method

    magnetic single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Frequency In Hertz

    400.0

  • Test Data Document

    81349-mil-prf-39019 specification

  • Terminal Type And Quantity

    2 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...