Circuit Breakers

CIRCUIT BREAKER

WC375/16-002

5925-01-092-3300

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    4 slot

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac single location

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac single location

  • Mounting Slot Width

    0.094 inches nominal

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance re

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.000 inches nominal

  • Body Height

    3.375 inches nominal

  • Terminal Type And Quantity

    2 compression

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Frequency In Hertz

    60.0 single location

  • Body Length

    6.000 inches nominal

  • Body Style

    single pole type

  • Boss Height

    0.125 inches nominal

  • Specification/Standard Data

    81348-w-c-375/16 government specification

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Trip Release Method

    thermal-magnetic single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Body Width

    1.375 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...