AA55571/07-008

Circuit Breakers

CIRCUIT BREAKER

AA55571/07-008

5925-01-092-9694

5925 - Circuit Breakers

Federal Commercial Item Description

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and salt spray proof and fungus resistant

  • Case Material

    plastic

  • Reset Method

    automatic

  • Center To Center Distance Between Terminals Parallel To Length

    1.060 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Unthreaded Mounting Hole Diameter

    0.195 inches minimum and 0.225 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes dc single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Body Width

    1.880 inches nominal

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Specification/Standard Data

    58536-aa55571/07-008 government specification

  • Overall Length

    3.160 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...