AP-1-1-7-2-202
Circuit Breakers
CIRCUIT BREAKER
AP-1-1-7-2-202
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Trip Release Method
magnetic-hydraulic single location
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.010 minimum at 400 pct single location and 0.200 minimum at 200 pct single location and 6.000 maximum at 200 pct single location and 0.500 maximum at 400 pct single location
-
Thread Series Designator
unef
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 50.0 dc single location
-
Bushing Length
0.380 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
thd bushing w/panel seal
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Body Length
1.500 inches maximum
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location
-
Frequency In Hertz
400.0 single location
-
Terminal Type And Quantity
2 wire hook
-
Reset Method
manual
-
Actuator Position Designation
at pole one