Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Length

    1.781 inches maximum

  • Mounting Surface To Terminal End Distance

    1.218 inches nominal

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Unpackaged Unit Weight

    62.0 grams

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Bushing Length

    0.250 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 5000.0 dc single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...