29-1362376-1
Circuit Breakers
CIRCUIT BREAKER
29-1362376-1
General Dynamics C4 Systems Inc.
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
single pole type
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Trip Release Method
thermal-magnetic single location
-
Nominal Thread Size
0.437 inches
-
Pole Quantity
1
-
Circuit Protection Type
undervoltage single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 100 pct single location and 0.115 maximum at 100 pct single location
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
1.343 inches maximum
-
Terminal Type And Quantity
2 screw
-
Special Features
threaded bushing w/panel seal type mount
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Center To Center Distance Between Terminals Parallel To Length
1.000 inches nominal
-
Reset Method
manual
-
Thread Series Designator
uns
-
Trip Release Ambient Temp Rating
-55.0 deg celsius minimum single location and 121.0 deg celsius maximum single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
0.45 dc single location