APL4432-2
Circuit Breakers
CIRCUIT BREAKER
APL4432-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac first location
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Body Width
3.750 inches maximum
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc third location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc third location
-
Pole Quantity
5
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 1000.0 dc all locations
-
Manual Actuator Type And Quantity
5 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc fourth location
-
Case Material
plastic
-
Body Length
2.490 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac second location
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
10 threaded hole
-
Frequency In Hertz
60.0 first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Frequency In Hertz
60.0 second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.240 minimum at 200 pct all locations and 0.800 maximum at 200 pct all locations
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc fifth location
-
External Actuator Linkage Arrangement
one, two, three, four, and five linked
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes dc fifth location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc fourth location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Surface To Terminal End Distance
2.475 inches maximum