313C748G20/452D377G0

Circuit Breakers

CIRCUIT BREAKER

313C748G20/452D377G0

5925-01-094-3466

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Terminal Type And Quantity

    6 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    10.875 inches nominal

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    60.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    10.875 inches nominal

  • Body Width

    8.000 inches nominal

  • Mounting Surface To Terminal End Distance

    9.031 inches nominal

  • Body Length

    12.000 inches nominal

  • Special Features

    shunt trip 120vdc

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +650.0/+1300.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Features Provided

    adjustable trip release and high inrush protection

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...