8996789-5

Circuit Breakers

CIRCUIT BREAKER

8996789-5

5925-01-095-1542

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Unpackaged Unit Weight

    12.000 ounces

  • Mounting Slot Width

    0.154 inches minimum and 0.174 inches maximum

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 5.557 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.771 inches minimum and 4.791 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 125.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac and 5000.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Surface To Terminal End Distance

    3.167 inches minimum and 3.301 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac and 30.0 amperes dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct and 100.000 maximum at 200 pct

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...