8996789-4

Circuit Breakers

CIRCUIT BREAKER

8996789-4

5925-01-095-1543

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Mounting Slot Width

    0.154 inches minimum and 0.174 inches maximum

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.771 inches minimum and 4.791 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    3.167 inches minimum and 3.301 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 slot

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    12.000 ounces

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 5.357 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 125.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct single location and 100.000 maximum at 200 pct

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.