8996789-4

Circuit Breakers

CIRCUIT BREAKER

8996789-4

5925-01-095-1543

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Mounting Slot Width

    0.154 inches minimum and 0.174 inches maximum

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.771 inches minimum and 4.791 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    3.167 inches minimum and 3.301 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 slot

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    12.000 ounces

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.537 inches minimum and 5.357 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 125.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct single location and 100.000 maximum at 200 pct

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...