296790-0001

Circuit Breakers

CIRCUIT BREAKER

296790-0001

5925-01-095-9989

5925 - Circuit Breakers

Nai Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Terminal Type And Quantity

    8 tab w/screw

  • Nonturn Device Location

    at 12 oclock

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Actuator Position Designation

    at pole two

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Body Style

    multipole-single actuator type

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Nonturn Device Length

    0.130 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.200 maximum at 200 pct all locations

  • Body Width

    2.250 inches nominal

  • Internal Trip Release Configuration

    series trip third location

  • Bushing Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Thread Series Designator

    un

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Nonturn Device Radius

    0.656 inches nominal

  • Special Features

    poseidon,trident and combat system support equipment in weapons system

  • Unpackaged Unit Weight

    9.000 ounces

  • Internal Trip Release Configuration

    relay trip first location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...