Technical Characteristics
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Terminal Type And Quantity
8 tab w/screw
-
Nonturn Device Location
at 12 oclock
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Actuator Position Designation
at pole two
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
-
Body Style
multipole-single actuator type
-
Internal Trip Release Configuration
series trip second location
-
Manual Actuator Type And Quantity
1 toggle
-
Nonturn Device Length
0.130 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct all locations and 1.200 maximum at 200 pct all locations
-
Body Width
2.250 inches nominal
-
Internal Trip Release Configuration
series trip third location
-
Bushing Length
0.625 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Inclosure Protection Type For Which Designed
shock resistant and hermetically sealed and vibration resistant
-
Thread Series Designator
un
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Nonturn Device Radius
0.656 inches nominal
-
Special Features
poseidon,trident and combat system support equipment in weapons system
-
Unpackaged Unit Weight
9.000 ounces
-
Internal Trip Release Configuration
relay trip first location
-
Case Material