F7B340-53-48BB
Filters and Networks
FILTER,BAND PASS
F7B340-53-48BB
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.500 inches nominal
-
Reference Frequency Per Function
500.0 megahertz 1st band pass
-
Reference Frequency Per Function
500.0 megahertz 2nd band pass
-
Reference Frequency Per Function
500.0 megahertz 5th band pass
-
Input Impedance Per Function W/Load
75.0 ohms 1st band pass
-
Input Impedance Per Function W/Load
75.0 ohms 2nd band pass
-
Input Impedance Per Function W/Load
75.0 ohms 3rd band pass
-
Output Impedance Per Function W/Source Across Input
75.0 ohms 5th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 3rd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 4th band pass
-
Specified Frequencies Of Discrimination Per Function
100.00 megahertz 1st band pass and 200.00 megahertz 1st band pass and 800.00 megahertz 1st band pass and 16.00 gigahertz 1st band pass
-
Specified Frequencies Of Discrimination Per Function
100.00 megahertz 2nd band pass and 200.00 megahertz 2nd band pass and 800.00 megahertz 2nd band pass and 16.00 gigahertz 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
100.00 megahertz 3rd band pass and 200.00 megahertz 3rd band pass and 800.00 megahertz 3rd band pass and 16.00 gigahertz 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
100.00 megahertz 5th band pass and 200.00 megahertz 5th band pass and 800.00 megahertz 5th band pass and 16.00 gigahertz 4th band pass
-
Frequency Band Width Per Function
200.00 megahertz 1st band pass and 800.00 megahertz 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 2nd band pass and 10.0 maximum 2nd band pass and 10.0 maximum 2nd band pass and 70.0 minimum 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 3rd band pass and 10.0 maximum 3rd band pass and 10.0 maximum 3rd band pass and 70.0 minimum 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 4th band pass and 10.0 maximum 4th band pass and 10.0 maximum 4th band pass and 70.0 minimum 4th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 5th band pass and 10.0 maximum 5th band pass and 10.0 maximum 5th band pass and 70.0 minimum 5th band pass
-
Body Width
0.750 inches nominal
-
Reference Frequency Per Function
500.0 megahertz 3rd band pass
-
Reference Frequency Per Function
500.0 megahertz 4th band pass
-
Input Impedance Per Function W/Load
75.0 ohms 4th band pass
-
Input Impedance Per Function W/Load
75.0 ohms 5th band pass
-
Output Impedance Per Function W/Source Across Input
75.0 ohms 1st band pass
-
Output Impedance Per Function W/Source Across Input
75.0 ohms 2nd band pass
-
Output Impedance Per Function W/Source Across Input
75.0 ohms 3rd band pass
-
Output Impedance Per Function W/Source Across Input
75.0 ohms 4th band pass
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
2 terminal
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 5th band pass
-
Functional Terminal Type And Quantity
1 tab,solder lug input
-
Functional Terminal Type And Quantity
1 tab,solder lug output
-
Specified Frequencies Of Discrimination Per Function
100.00 megahertz 4th band pass and 200.00 megahertz 4th band pass and 800.00 megahertz 4th band pass and 16.00 gigahertz 4th band pass
-
Body Material
metal
-
Frequency Band Width Per Function
200.00 megahertz 2nd band pass and 800.00 megahertz 2nd band pass
-
Frequency Band Width Per Function
200.00 megahertz 3rd band pass and 800.00 megahertz 3rd band pass
-
Frequency Band Width Per Function
200.00 megahertz 4th band pass and 800.00 megahertz 4th band pass
-
Frequency Band Width Per Function
200.00 megahertz 5th band pass and 800.00 megahertz 5th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 1st band pass and 10.0 maximum 1st band pass and 10.0 maximum 1st band pass and 70.0 minimum 1st band pass