WC375/18-001

Circuit Breakers

CIRCUIT BREAKER

WC375/18-001

5925-01-096-4664

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    thermal-magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Body Length

    5.990 inches minimum and 6.010 inches maximum

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Height

    3.365 inches minimum and 3.385 inches maximum

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.365 inches minimum and 1.385 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Specification/Standard Data

    81348-w-c-375/18 government specification

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Body Width

    4.115 inches minimum and 4.135 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct all locations

  • ~1

    data on certain environmental and performance re

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.490 inches minimum and 4.510 inches maximum

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    5.366 inches minimum and 5.386 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.365 inches minimum and 1.385 inches maximum

  • Case Material

    plastic

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...