W-C-375/10

Circuit Breakers

CIRCUIT BREAKER

W-C-375/10

5925-01-096-4675

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Specification/Standard Data

    81348-w-c-375/10 government specification

  • Body Style

    single pole type

  • Body Width

    1.370 inches minimum and 1.380 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Terminal Type And Quantity

    2 compression

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location

  • Case Material

    plastic

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Length

    6.310 inches nominal

  • ~1

    data on certain environmental and performance re

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Height

    3.380 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Trip Release Method

    thermal-magnetic single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...