M39019/05-214

Circuit Breakers

CIRCUIT BREAKER

M39019/05-214

5925-01-096-4684

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Body Width

    1.906 inches minimum and 1.937 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.797 inches minimum and 1.828 inches maximum

  • Pole Quantity

    3

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    150.0 grams

  • Test Data Document

    81349-mil-c-39019 specification

  • Terminal Type And Quantity

    6 wire hook

  • Specification/Standard Data

    81349-mil-c-39019/5 government specification

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Case Material

    metal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes ac all locations and 750.0 milliamperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc

  • Trip Release Method

    magnetic all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...