W-C-375/17

Circuit Breakers

CIRCUIT BREAKER

W-C-375/17

5925-01-096-4694

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Actuator Position Designation

    at pole one

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.490 inches minimum and 4.510 inches maximum

  • Mounting Slot Width

    0.178 inches minimum and 0.198 inches maximum

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    3.365 inches minimum and 3.385 inches maximum

  • Body Style

    multipole-single actuator type

  • Terminal Type And Quantity

    4 compression

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.052 inches minimum and 5.072 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.552 inches minimum and 2.572 inches maximum

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Mounting Facility Type And Quantity

    2 slot

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    360.000 maximum at 200 pct all locations

  • Body Length

    5.990 inches minimum and 6.010 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.365 inches minimum and 1.385 inches maximum

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Pole Quantity

    2

  • Body Width

    2.740 inches minimum and 2.760 inches maximum

  • Reset Method

    manual

  • ~1

    data on certain environmental and performance re

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...